7705 SAR Interfaces
332
Interface Configuration Guide
3HE 11011 AAAC TQZZA Edition: 01
thresholds
Syntax thresholds
Context config>external-alarms>alarm
Description This command enables the context to configure the thresholds for the specified alarm.
Default n/a
analog
Syntax analog
Context config>external-alarms>alarm>thresholds
Description This command enables the context to configure analog trigger thresholds for the specified
alarm.
Default n/a
level
Syntax [no] level {lt | gt} millivolts
Context config>external-alarms>alarm>thresholds>analog
Description This command configures the analog voltage level thresholds for the specified alarm.
The analog input level threshold cannot be changed from no level when there are no analog
inputs configured as triggers. When all analog inputs are removed from the trigger list, the
level is automatically changed to no level. The analog input level threshold cannot be
changed to no level when there is analog input in the trigger list. When the first analog input
is added to the alarm trigger, the level is automatically changed to gt 0.
The no form of this command removes the analog voltage level threshold.
Default no level
Parameters lt — specifies a less-than value
gt — specifies a greater-than value
millivolts — specifies the voltage level in millivolts
Values 0 to 75000