Interface Configuration Guide 7705 SAR Interfaces
Edition: 01 3HE 11011 AAAC TQZZA 277
3.11.2.23 Configuring Serial Ports for Raw Socket Transport
Use the following CLI syntax to configure raw socket parameters on an RS-232 serial
port.
CLI Syntax: port port-id
serial
rs232
socket socket-id
description description-string
encap-type raw
rx
eop
idle-timeout milliseconds
length bytes
special-char value
exit
unsquelch-delay seconds
squelch-reset
exit
tx
inter-session-delay
milliseconds
exit
no shutdown
exit
exit
exit
3.11.3 Configuring SCADA Bridge Parameters
Use the following CLI commands to configure SCADA bridge parameters on an
Integrated Services card.
CLI Syntax: scada bridge-id
branch branch-id
description description-string
gain
input decibels
output decibels
Note: Raw sockets are only supported on RS-232 serial ports.