Interface Configuration Guide 7705 SAR Interfaces
Edition: 01 3HE 11011 AAAC TQZZA 205
config>ext-alarms>alarm# log
config>ext-alarms>alarm# trigger any alarm-1/1.a-1
alarm-1/1.a-2 alarm.d-1 alarm.d-2 alarm.d-3 alarm.d-4
config>ext-alarms>alarm# severity major
config>ext-alarms>alarm# thresholds
config>ext-alarms>alarm>thresholds# analog level lt 4
config>ext-alarms>alarm>thresholds# exit
config>ext-alarms>alarm# exit
config>ext-alarms# exit
The following CLI syntax shows an example of configuring custom alarms on
Ethernet ports.
Example: config# external-alarms input port-1/1/5
config>ext-alarms>in# name “CABINET-DOOR”
config>ext-alarms>in# description “Front Panel Access
Door Sensor”
config>ext-alarms>in# exit
config# external-alarms input port-1/1/6
config>ext-alarms>in# name “REAR-PANEL”
config>ext-alarms>in# description “Rear Maintenance
Panel Sensor”
config>ext-alarms>in# exit
config# external-alarms alarm 1
config>ext-alarms>alarm# description “Local Security
Breach”
config>ext-alarms>alarm# trigger “CABINET-DOOR”
“REAR-PANEL”
config>ext-alarms>alarm# severity critical
config>ext-alarms>alarm# no shutdown
config>ext-alarms>alarm# exit
Use the show external-alarms input command to display Ethernet port alarm input
information.
*ALU-A# show external-alarms input
===========================================================================
External Alarm Input Summary
===========================================================================
Input Id Name Type Admin Value Alarm State
---------------------------------------------------------------------------
alarm.d-1 Digital-In Up Open Ok
alarm.d-2 Digital-In Up Open Ok
alarm.d-3 Digital-In Up Open Ok
alarm.d-4 Digital-In Up Open Ok
port-1/5/1 CABINET-DOOR Oper-State Up Down Alarm-Detected
port-1/6/1 REAR-PANEL Oper-State Up Up Ok
===========================================================================