Interface Configuration Guide 7705 SAR Interfaces
Edition: 01 3HE 11011 AAAC TQZZA 409
Default high
Parameters high — the output control lead is forced on
low — the output control lead is forced off
end-to-end — the output control lead follows that of the remote end
dsr-dtr
Syntax dsr-dtr {high | low}
Context config>port>serial>rs232>control-lead>output
config>port>serial>v35>control-lead>output
Description This command configures the Data Set Ready (DSR) or Data Terminal Ready (DTR) output
control lead. The output signal that is sent depends on the device-gender setting. For a DCE
device, the outputs signal is DSR. For a DTE device, the output signal is DTR.
This command is valid only for RS-232 and V.35 interfaces.
Default high
Parameters high — the output control lead is forced on
low — the output control lead is forced off
i-c
Syntax i-c {high | low | end-to-end}
Context config>port>serial>x21>control-lead>output
Description This command configures the Indication (I) or Control (C) output control lead. The output
signal that is sent depends on the device-gender setting. For a DCE device, the output signal
is I. For a DTE device, the output signal is C.
This command is valid only for an X.21 interface.
Default high
Parameters high — the output control lead is forced on
low — the output control lead is forced off
end-to-end — the output control lead follows that of the remote end