Interface Configuration Guide 7705 SAR Interfaces
Edition: 01 3HE 11011 AAAC TQZZA 431
lb2er-sd — reports line signal degradation BER (bit interleaved parity) errors
Default line signal degradation BER alarms are not issued
lb2er-sf — reports line signal failure BER errors
Default line signal failure BER alarms are issued
slof — reports section loss of frame errors
Default section loss of frame alarms are issued
slos — reports a section loss of signal error on the transmit side
Default section loss of signal alarms are issued
lrei — reports a line error condition raised by the remote end as a result of b1 errors
received from this node. When configured, line error alarms are raised but not
cleared.
Default line error alarms are not issued
section-trace
Syntax section-trace {increment-z0 | byte value | string string}
Context config>port>sonet-sdh
Description This command configures the section trace bytes in the SONET section header to
interoperate with some older versions of ADMs or regenerators that require an incremental
STM ID. You can explicitly configure an incremental STM value rather than a static one in the
SDH overhead by specifying an increment-z0 value.
The increment-z0 parameter is not supported on the 4-port OC3/STM1 / 1-port OC12/STM4
Adapter card.
Default byte 0x1
Parameters increment-z0 — configures an incremental STM ID instead of a static value
value — sets values in SONET header bytes
Values 0 to 255 or 0x00 to 0xFF
Default 0x1
string — specifies a text string that identifies the section
Values a string up to 16 bytes
speed
Syntax speed {oc3}
no speed