7705 SAR Interfaces
438
Interface Configuration Guide
3HE 11011 AAAC TQZZA Edition: 01
keepalive
Syntax keepalive time-interval [dropcount drop-count]
no keepalive
Context config>port>sonet-sdh>path>ppp
Description This command enables the sending of keepalive echo messages on a 4-port OC3/STM1
Clear Channel Adapter card and configures the time between messages and how many
reports can be missed before the link is brought down.
The no form of this command disables the sending of echo requests.
Default keepalive 10 dropcount 3
Parameters time-interval — the time interval, in seconds, that echo requests are issued
Values 1 to 60
Default 10
drop-count — the number of keepalive messages that can be missed before the link is
brought down
Values 1 to 255
Default 3
report-alarm
Syntax [no] report-alarm [pais] [plop] [prdi] [pplm] [prei] [puneq]
Context config>port>sonet-sdh>path
Description This command enables logging of SONET/SDH path alarms for a SONET/SDH port.
The no form of this command disables logging of the specified alarms.
Parameters pais — reports path alarm indication signal errors. When configured, path alarm
indication signal alarms are raised and cleared.
Default path alarm indication signal alarms are not issued
plop — reports path loss of pointer errors, per tributary. When configured, path loss of
pointer alarms are raised but not cleared.
Default path loss of pointer alarms are issued
prdi — reports path remote defect indication errors. When configured, path remote
defect indication alarms are raised and cleared.
Default path remote defect indication alarms are not issued