Interface Configuration Guide 7705 SAR Interfaces
Edition: 01 3HE 11011 AAAC TQZZA 49
On the CLI for the 7705 SAR-Ax, the slot/mda identifier for Ethernet ports is 1/1 and
for the GNSS RF port is 1/2.
On the CLI for the 7705 SAR-H, the slot/mda identifier for Ethernet ports is 1/1. The
chassis has two slots for modules (the 4-port T1/E1 and RS-232 Combination
module, the GPS Receiver module, and the 4-port SAR-H Fast Ethernet module). On
the CLI, the slot/mda identifier for a module installed in the first slot position is 1/2
and for a module installed in the second slot position is 1/3. Ethernet ports are
identified as 1/1/1 through 1/1/8. Module ports are identified as 1/2/port-num for
modules installed in the first slot position and 1/3/port-num for modules installed in
the second slot position.
On the CLI for the 7705 SAR-Hc, the slot/mda identifier for Ethernet ports is 1/1 and
for RS-232 ports is 1/2. Ethernet ports are identified as 1/1/1 through 1/1/6 and
RS-232 ports are identified as 1/2/1 and 1/2/2.
On the CLI for the 7705 SAR-M, the slot/mda identifier for T1/E1 ports is 1/2 and for
Ethernet ports is 1/1. For those variants of the chassis that have a module slot, the
slot/mda identifier for the module on the CLI is 1/3. The 7705 SAR-M variants with
module slots support the following modules: GPON module, 6-port DSL Combination
module, 8-port xDSL module, CWDM OADM module, 2-port 10GigE (Ethernet)
module, and 6-port SAR-M Ethernet module. T1/E1 ports are identified as 1/2/1
through 1/2/16 for those variants of the chassis with T1/E1 ports. Ethernet ports for
all variants of the 7705 SAR-M are identified as 1/1/1 through 1/1/7. Those variants
of the chassis that have module slots identify module ports as 1/3/port-num.
On the CLI for the 7705 SAR-W, the slot/mda identifier for the Ethernet ports is 1/1.
Ethernet ports are identified as 1/1/1 through 1/1/5. The 7705 SAR-W also has an
internal (virtual) port used for in-band Ethernet management connection. The virtual
port is identified as vrtl-mgmt on the CLI and as 1/1/6 via SNMP.
On the CLI for the 7705 SAR-Wx, the slot/mda identifier for the Ethernet ports is 1/1
and 1/2 for the xDSL port. Ethernet ports for the Ethernet-only variant and the
Ethernet and PoE+ variant are identified as 1/1/1 through 1/1/5. For the variant
supporting Ethernet ports and an xDSL port, the Ethernet ports are identified as 1/1/1
through 1/1/4 and the DSL port is identified as 1/2/1 through 1/2/4.
On the CLI for the 7705 SAR-X, the slot/mda identifier is specified as 1 for T1/E1
ports and 2 or 3 for Ethernet ports. The port number is specified as a variable that
can have a value from 1 to 8 for T1/E1 ports or 1 to 7 for Ethernet ports, depending
on how the port is configured.