Interface Configuration Guide 7705 SAR Interfaces
Edition: 01 3HE 11011 AAAC TQZZA 509
hold-time — specifies the delay time, in tenths of a second, before switching to a newly
selected active subgroup from the existing active subgroup. The timer delay applies
only if the existing subgroup remains operationally up. If a value of 0 or no value is
specified, the switchover occurs immediately. If a value of infinite is specified, no
switchover will occur as long as the subgroup remains up; this setting can be
overridden with the tools>perform>force>lag-id command. LACP must be enabled
on the LAG.
Values 0 to 2000 | infinite
standby-signaling
Syntax standby-signaling [lacp | power-off]
no standby-signaling
Context config>lag
Description This command specifies how the state of a member port is signaled to the remote side when
the status corresponding to this member port has a standby value.
The no form of this command turns off standby signaling.
Parameters lacp — specifies that lacp is active
power-off — specifies that the standby port transmitter is disabled