7705 SAR Interfaces
516
Interface Configuration Guide
3HE 11011 AAAC TQZZA Edition: 01
keepalive
Syntax keepalive time-interval
no keepalive
Context config>port>tdm>ds1>channel-group>cisco-hdlc
config>port>tdm>e1>channel-group>cisco-hdlc
config>port>serial>v35>channel-group>cisco-hdlc
config>port>serial>x21>channel-group>cisco-hdlc
Description This command configures the interval, in seconds, used to send periodic keepalive packets.
The receiver process expects to receive a keepalive packet every keepalive interval. The link
is declared down if the receiver process does not receive a keepalive within the time-out
interval. The link is declared up when the number of continual keepalive packets received
equals the up-count. The nodes at the two endpoints of the cHDLC link must be provisioned
with the same values.
The no form of this command returns the keepalive interval to the default value.
Default 10
Parameters time-interval — sets the interval, in seconds, used to send periodic keepalive packets
Values 0 to 300. A value of 0 means no keepalive packets are sent.
up-count
Syntax up-count up-count
no up-count
Context config>port>tdm>ds1>channel-group>cisco-hdlc
config>port>tdm>e1>channel-group>cisco-hdlc
config>port>serial>v35>channel-group>cisco-hdlc
config>port>serial>x21>channel-group>cisco-hdlc
Description This command configures the number of continual keepalive packets that have to be received
in order to declare the link up. The nodes at the two endpoints of the cHDLC link must be
provisioned with the same values.
The no form of this command returns the up-count to the default value.
Default 1
Parameters up-count — sets the number of continual keepalive packets that must be received in
order to declare the link up
Values 1 to 3

Table of Contents