4 Commissioning
BU 0200 en-3118 107
Details of DIP switch S1: 5/4 and 3
(values underlined in brackets)
= (relevant parameter / source of function), e.g.: Parameter (P420[01])
= {Function} e.g..: {01} "Enable right"
** only if present (devices without "Safe stop" function)
The functions of potentiometers*** P1 and P2 correspond to those of devices without an AS interface (see table above).
With DIP switches 5 and 4 in the OFF position (default setting), the digital inputs are also active. The functions then correspond
to those of devices without an AS interface (table above). In all other DIP switch combinations the functions of the digital inputs
are deactivated.
ASi OUT1 and ASi OUT2 loop the signal level (High / Low) of digital inputs 1 and 2.
Pos: 23 6 /Allg emein/ Allg emeing ültig e Mod ule/---------Sei tenumbr uch ko mpakt --------- @ 13\mod_1476369695906_0.docx @ 2265495 @ @ 1
Applies to devices SK 20xE, SK 21xE (without on board AS interface)
DIP Functions as per the list of digital functions (P420)
Functions as per the list of
analogue functions (P400)
5 4 3
off off off
{01} "enable R"
{02} "enable L"
P420 [03]*
{04} "Fixed freq1"
=5Hz (P465[01])
P420 [04]*
{05} "Fixed freq2"
=10Hz (P465[02])
{01} "F setpoint"
{15} "Ramp"
off on off
{01} "Enable R" {02} "Enable L"
{12} "Quit" {05} "F max" {04} "F min"
on on off
{50} "F Arr Bit0
=5Hz (P465[01])
{51} "F Arr Bit1"
=10Hz (P465[02])
{52} "F Arr Bit2"
=20Hz (P465[03])
{53} "F Arr Bit3"
=35Hz (P465[04])
{05} "F max" {15} "Ramp"
off off on
The functions of the digital inputs are inactive (control via system bus), however, the
settings made in parameters (P420 [01 … 04]) result in the activation of the
correspondingly parametrised input, for the functions designated with ..² in the function
list (e.g.: {11}²= "Quick stop).
P400 [01]
{01} "F setpoint"
P400 [02]
{15} "Ramp"
P420 [01]
no function
P420 [02]
no function
P420 [03]
{04} "Fixed freq1"
=5Hz (P465[01])
P420 [04]
{05} "Fixed freq2"
=10Hz (P465[02])
off on on
"Encoder track A" "Encoder track B" {01} "Enable R" {01} "F setpoint" {05} "F max"
on off on
{01} "Enable R" {10} "Block"
{01} "F setpoint" {05} "F max"
on on on
=10Hz (P465[02])
=20Hz (P465[03])
{53} "F Arr Bit3"
=35Hz (P465[04])
{05} "F max" {15} "Ramp"
Applies to devices SK 22xE, SK 23xE (without AS interface on board)
DIP Functions as per the list of digital functions (P420)
Functions as per the list of digital outputs
(P434)
5 4 3
off off off
{01} "Enable
R“
{02} "Enable
L“
P480 [03]*
{04} "Fixed
freq. 1"
P480 [04]*
{12} "Quit"
P481 [01]*
{07} "Error"
{18}
"Standby"
"DigIn1" "DigIn2"
off on off
{04} "Fixed
freq. 1"
=5Hz (P465[01])
{05} "Fixed
freq. 2"
=10Hz (P465[02])
{06}
freq. 3"
{07}
freq. 4" =35Hz
{07} "Error"
{18}
"Standby"
"DigIn1" "DigIn2"
on off off
{47} "Freq. +" {48} "Freq. -" {07} "Error"
"DigIn1" "DigIn2"
on on off
{51}
B1"
{52}
B2"
{53}
B3"
{14} "Remote
control"
{07} "Error"
{18}
"Standby"
"DigIn1" "DigIn2"
off off on
The functions of the digital inputs are inactive (control via system bus),
however, the settings made in parameters (P480 [01 … 04]) result in the
activation of the correspondingly parametrised bits, for the functions
designated with ..² in the function list (e.g.: {11}²= "Quick stop).
P481 [01]
{07}
"Error"
P481 [02]
{18}
"Standby"
"DigIn1" "DigIn2"
P480 [01]
no function
P480 [02]
no function
{04} "Fixed
freq. 1"
P480 [04]
{12} "Quit"
off on on
{14} "Remote
control"
freq. 1"
freq. 2"
freq. 3"
{07} "Error"
{18}
"Standby"
"DigIn1" "DigIn2"
on off on
{47} "Freq. +"
{48}
"Freq. -"
{07} "Error"
"DigIn1" "DigIn2"
on on on
{14} "Remote
control"
B0"
B1"
B2"
{07} "Error"
{18}
"Standby"
"DigIn1" "DigIn2"