EasyManua.ls Logo

Nord Drivesystems NORDAC FLEX SK 210E Series - Page 165

Nord Drivesystems NORDAC FLEX SK 210E Series
284 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 Parameter
BU 0200 en-3118 165
Pos: 41 9 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par amet er/ Par amet erau fli st ung (P 000 .. .)/P 400- P499 /Par amet er P400 F kt. S oll wer tei nga ng [S K 2x5E ] @ 2\mod_1346931796285_388.docx @ 42354 @ @ 1
P400 [-01]
...
[-09]
Function Setpoint inputs
(Function of setpoint inputs)
SK 2x5E
P
0 ... 36
{ [-01] = 1 }
{ [-02] = 15 }
{ [-03] = 0 }
{ [-04] = 0 }
{ [-05] = 1 }
{ [-06] = 0 }
{ [-07] = 1 }
{ [-08] = 0 }
{ [-09] = 0 }
[-01]
Potentiometer 1, Function of the potentiometer P1 integrated into the FI. DIP switches 4/5
must be "Off" so that the function can be influenced by this parameter setting
(chapter
4.3.2.2)
[-02]
Potentiometer 2, as for potentiometer 1
[-03]
External Analogue input 1, AIN1 of the first I/O extension (SK xU4-IOE)
[-04]
External Analogue input 2, AIN2 of the first I/O extension (SK xU4-IOE)
[-05]
Setpoint module
[-06]
Digital input 2, can be set to pulse signal evaluation via parameter P420 [-02] =26 or 27.
The pulses are then evaluated in the FI as an analogue signal according to the function
which is set here.
[-07]
Digital input 3, can be set to pulse signal evaluation via parameter P420 [-03] =26 or 27.
The pulses are then evaluated in the FI as an analogue signal according to the function
which is set here.
[-08]
External A.in. 1 2nd IOEE,
"External analogue input 1 2nd IOE"
, AIN1 of the second I/O
extension (SK xU4-IOE) (= Analogue input 3)
[-09]
External A.in. 2 2nd IOE, "External analogue input 2 2nd IOE", AIN2 of the second I/O
extension (SK xU4-IOE) (= Analogue input 4)
The basic versions of the SK 2x5E devices do not have an analogue input. An analogue function
can only be used by using options (array [-01]...[-05] and [-08]…[-09]) or using digital input 2 or 3
(array [-06]...[-07]).
... Setting values below.
Pos: 42 0 /Allg emein/ Allg emeing ültig e Mod ule/---------Sei tenumbr uch ko mpakt --------- @ 13\mod_1476369695906_0.docx @ 2265495 @ @ 1