5 Parameter
BU 0200 en-3118 165
Pos: 41 9 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par amet er/ Par amet erau fli st ung (P 000 .. .)/P 400- P499 /Par amet er P400 – F kt. S oll wer tei nga ng [S K 2x5E ] @ 2\mod_1346931796285_388.docx @ 42354 @ @ 1
P400 [-01]
...
[-09]
Function Setpoint inputs
(Function of setpoint inputs)
SK 2x5E
P
0 ... 36
{ [-01] = 1 }
{ [-02] = 15 }
{ [-03] = 0 }
{ [-04] = 0 }
{ [-05] = 1 }
{ [-06] = 0 }
{ [-07] = 1 }
{ [-08] = 0 }
{ [-09] = 0 }
Potentiometer 1, Function of the potentiometer P1 integrated into the FI. DIP switches 4/5
must be "Off" so that the function can be influenced by this parameter setting
(chapter
4.3.2.2)
Potentiometer 2, as for potentiometer 1
External Analogue input 1, AIN1 of the first I/O extension (SK xU4-IOE)
External Analogue input 2, AIN2 of the first I/O extension (SK xU4-IOE)
Digital input 2, can be set to pulse signal evaluation via parameter P420 [-02] =26 or 27.
The pulses are then evaluated in the FI as an analogue signal according to the function
Digital input 3, can be set to pulse signal evaluation via parameter P420 [-03] =26 or 27.
The pulses are then evaluated in the FI as an analogue signal according to the function
External A.in. 1 2nd IOEE,
"External analogue input 1 2nd IOE"
, AIN1 of the second I/O
extension (SK xU4-IOE) (= Analogue input 3)
External A.in. 2 2nd IOE, "External analogue input 2 2nd IOE", AIN2 of the second I/O
extension (SK xU4-IOE) (= Analogue input 4)
The basic versions of the SK 2x5E devices do not have an analogue input. An analogue function
can only be used by using options (array [-01]...[-05] and [-08]…[-09]) or using digital input 2 or 3
... Setting values below.
Pos: 42 0 /Allg emein/ Allg emeing ültig e Mod ule/---------Sei tenumbr uch ko mpakt --------- @ 13\mod_1476369695906_0.docx @ 2265495 @ @ 1