5 Parameter
BU 0200 en-3118 167
18 =
Curve travel calculator, via the external analogue input (P400 [-03] or P400 [-04]) or via
the BUS (P546 [-01 .. -03]) the master receives the actual speed from the slave. From its
own speed, the slave speed and the guide speed, the master calculates the actual
setpoint speed, so that neither of the two drives travels faster than the guide speed in the
curve.
19 =
Servo mode torque, in servo mode ((P300)= "1") the motor torque can be set / limited
using this function. As of firmware version V1.3 this function is also without speed
feedback, however it can be used at a lower quality.
25 =
Transfer Factor Gearing
, "Gearing Transfer Factor", is a multiplier to compensate for the
variable transfer of a setpoint value. E.g.: Setting of the transformation between the
master and the slave by means of a potentiometer.
26 =
…reserved, for Posicon, see BU0210
30 =
Motor temperature: enables measurement of the motor temperature with a
KTY-84 temperature sensor ( Section 4.4 "KTY84-130 connection")
33 =
Setpoint Torque Proc. cntrl.
, "Setpoint torque process controller", for even distribution
of the torques to coupled drive units (e.g.: S-roller drive). This function is also possible
with the use of ISD control.
34 =
d-correction F process -
(diameter correction, frequency PI / process controller).
35 =
d-correction Torque -
(diameter correction, torque).
36 =
d-correction F + Torque - (diameter correction, frequency for PI / process controller and
torque)
*) For further details of the PI and process controller, please refer to Section
8.2 "Process
controller".
**) The limits of these values are formed by the parameters >minimum frequency auxiliary
setpoint values< (P410) and the parameter >maximum frequency auxiliary setpoint values<
(P411), whereby the limits defined by (P104) and (P105) cannot be undershot or overshot.
Pos: 42 2 /Allg emein/ Allg emeing ültig e Mod ule/---------Sei tenumbr uch ko mpakt --------- @ 13\mod_1476369695906_0.docx @ 2265495 @ @ 1

Table of Contents

Other manuals for Nord Drivesystems NORDAC FLEX SK 210E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nord Drivesystems NORDAC FLEX SK 210E Series and is the answer not in the manual?

Nord Drivesystems NORDAC FLEX SK 210E Series Specifications

General IconGeneral
BrandNord Drivesystems
ModelNORDAC FLEX SK 210E Series
CategoryInverter
LanguageEnglish

Related product manuals