8 Additional information
BU 0200 en-3118 269
b) 400V frequency inverter
The following data is based on an output of 2.2 kW using a 230/400 V motor winding. 400/690 V
windings are used for 3 kW and higher.
They apply for IE1 and IE2 motors. It should be noted that these details may deviate slightly, as
motors are subject to certain manufacturing tolerances. It is recommended that the resistance of the
connected motor is measured by the frequency inverter (P208 / P220).
Motor
(IE1)
SK …
Frequency
inverter
SK 2xxE-…
M
N
*
[Nm]
Parameterisation data of frequency inverter
F
N
[Hz]
n
N
[min-1]
I
N
[A]
U
N
[V]
P
N
[kW]
cos Ï•
Y/Δ
R
St
[Ω]
100L/4 221-340-A 14.6 50 1415 5.0 400 2.2 0.78 Y 2.78
160M/4 112-340-A 72.2 50 1455 20.9 400 11.0 0.85 Δ 1.08
* at rated point
Motor
(IE2)
SK …
Frequency
inverter
SK 2xxE-…
M
N
*
[Nm]
Parameterisation data of frequency inverter
F
N
[Hz]
n
N
[min-1]
I
N
[A]
U
N
[V]
P
N
[kW]
cos Ï•
Y/Δ
R
St
[Ω]
90SH/4 111-340-A 7.53 50 1430 2.46 400 1.1 0.8 Y 4.96
100LH/4 221-340-A 14.6 50 1445 4.76 400 2.2 0.79 Y 1.73
132SH/4 551-340-A 36.5 50 1455 10.82 400 5.5 0.83 Δ 1.84
160MH/4 112-340-A 72.2 50 1465 20.5 400 11.0 0.85 Δ 0.78
180LH/4 222-340-A 145 50 1475 40.8 400 22.0 0.86 Δ 0.31
* at rated point