1 General
BU 0200 en-3118 31
Size valid description
1 - 3 For 240 V for 1
phase models or
500V for 3
phase models
only:
“Suitable For Use On A Circuit Capable Of Delivering Not More Than 65 000 rms Symmetrical
Amperes, ____ Volt maximum”,
“When Protected by Circuit Breaker (inverse time trip type) in accordance with UL 489, rated
______ Amperes, and _______Volts”, as listed in
1)
.
For 120 V,
240 V, 400 V,
500 V models
only:
“Suitable For Use On A Circuit Capable Of Delivering Not More Than 100 000 rms Symmetrical
Amperes, ____ Volts Maximum” and minimum one of the two following alternatives.
When used together with Accessory SK TU4-MSW:
“Suitable For Use On A Circuit Capable Of Delivering Not More Than 10 000 rms Symmetrical
Amperes, ____ Volts Maximum” and minimum one of the two following alternatives.
1. “When Protected by Fuses manufactured by Bussmann, type ______”, as listed in
1)
.
2. “When Protected by class RK5 Fuses or faster or when Protected by High-Interrupting
Capacity, Current Limiting Class CC, G, J, L, R, T, etc. Fuses, rated ______ Amperes, and
_____ Volts”, as listed in
1)
.
Motor group
installation
(Group fusing):
“Suitable for motor group installation on a circuit capable of delivering not more than 100 000
rms symmetrical amperes, 500 V max” “When Protected by class RK5 Fuses or faster, rated
30_Amperes”
“Suitable for motor group installation on a circuit capable of delivering not more than 100 000
rms symmetrical amperes, 500 V max” “When Protected by High-Interrupting Capacity, Current
Limiting Class CC, G, J, L, R, T, etc. Fuses rated 30 Amperes”
“Suitable for motor group installation on a circuit capable of delivering not more than 10 000
rms symmetrical amperes, 500 V max” “When Protected by Circuit Breaker (inverse time trip
type) in accordance with UL 489, rated 30 Amperes and 500 Volts min
differing data
CSA:
If device is used for Canadian market and bears the cUL Listing mark: “For Canada SCCR is
limited to 5 000 rms Symmetrical Amperes.”.
Marking not required for UL only marked devices.
4 Models
-551-323-A;
-751-323-A;
-112-323-A only:
“Suitable For Use On A Circuit Capable Of Delivering Not More Than 100 000 rms Symmetrical
Amperes, 240 Volts Maximum When Protected By High-Interrupting Capacity, Current Limiting
Type Fuses such as Class CC, G, J, L, R, T, etc., rated 300V/60A."
“Suitable For Use On A Circuit Capable Of Delivering Not More Than 10 000 rms Symmetrical
Amperes, 240 Volts Maximum When Protected By A Circuit Breaker Having An Interrupting
Rating Not Less Than 10 000 rms Symmetrical Amperes, 300 Volts Maximum."
Models
-112-340-A;
-152-340-A;
-182-340-A;
-222-340-A only:
“Suitable For Use On A Circuit Capable Of Delivering Not More Than 100 000 rms Symmetrical
Amperes, 500 Volts Maximum When Protected By High-Interrupting Capacity, Current Limiting
Type Fuses such as Class CC, G, J, L, R, T, etc., rated 600A/60A."
“Suitable For Use On A Circuit Capable Of Delivering Not More Than 10 000 rms Symmetrical
Amperes, 500 Volts Maximum When Protected By A Circuit Breaker Having An Interrupting
Rating Not Less Than 10 000 rms Symmetrical Amperes, 600 Volts Maximum."
1)
7.2
Pos: 51 /A llg em ein/ Allg em eing ülti ge M od ule/ ---------Seite numbr uch kompakt --------- @ 13\ mod_1476369695906_0.docx @ 2265495 @ @ 1

Table of Contents

Other manuals for Nord Drivesystems NORDAC FLEX SK 210E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nord Drivesystems NORDAC FLEX SK 210E Series and is the answer not in the manual?

Nord Drivesystems NORDAC FLEX SK 210E Series Specifications

General IconGeneral
BrandNord Drivesystems
ModelNORDAC FLEX SK 210E Series
CategoryInverter
LanguageEnglish

Related product manuals