Operating Parameters
B-7
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
16 Overpressure Setpoint Not Shown
Description:
If the pressure in the system exceeds this setting, an overpressure alarm is
triggered.
Value:
0 to 50 (percent) above the pressure setpoint (parameter 15)
Resolution:
Default:
0 (disabled)
Format:
Use:
This parameter is available only if the analog I/O board is installed in the melter.
17 Underpressure Setpoint Not Shown
Description:
If the pressure in the system falls below this setting, an underpressure alarm is
triggered.
Value:
0 to 50 (percent) below the pressure setpoint (parameter 15)
Resolution:
Default:
0
Format:
Use:
This parameter is available only if the analog I/O board is installed in the melter.
20 Temperature Units
Description:
Sets the units for temperature display.
Value:
C (degrees Celsius)
F (degrees Fahrenheit)
Resolution:
Default:
C
Format:
Use:
21 Overtemperature Delta
Description:
The number of degrees that the temperature of any component can exceed its
assigned setpoint temperature before an overtemperature fault (F3) occurs.
Value:
5 _C (10 _F) to 60 _C (110 _F)
Resolution:
1_C
1_F
Default:
15 _C (25_F)
Format:
Use: