Operating Parameters
B-6
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
Standard (contd.)
13 Change Hose 2 Output to Electric Gun Activation
Description:
Not in use
Value:
0 (disabled)
1 (enabled)
Resolution:
—
Default:
0 (disabled)
Format:
—
Use:
For Nordson electric guns that use a switching device to evaluate an electrical
signal sent by the melter through a special receptacle.
The operating parameter is not suitable for these melters.
14 Melter Inputs/Outputs Interlock
Description:
Serves as a safety lock during melter maintenance work. Prevents the melter
from being controlled externally via standard or optional inputs/outputs
Value:
0 (disabled)
1 (enabled)
Resolution:
—
Default:
0 (disabled)
Format:
—
Use:
Before beginning maintenance work to the melter, set the parameter to 1
(interlock enabled). External control of the melter is completely disabled until
the parameter is set to 0 (disabled) again.
15
Pressure Setpoint − Not Shown −
Description:
Used to set a percentage value of the maximum output pressure
(from 0 − 100 %).
Value:
0 to 100 (percent)
Resolution:
—
Default:
0 (disabled)
Format:
—
Use:
This parameter is available only if the analog I/O board is installed in the melter.
The pressure is displayed after the last gun temperature. The left display
indicates P (pressure), and the right display shows the pressure value.