Operating Parameters
B-5
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
10 Enable or Disable Password
Description:
Enables or disables the melter password. When password protection is
activated, component setpoint temperatures or melter operating parameters
can not be changed until a valid password is entered using parameter 0.
Value:
0 (disabled)
1 (enabled)
Resolution:
—
Default:
0
Format:
—
Use:
A password must first be created using parameter 11 before it can be enabled
or disabled with parameter 10.
11 Create Password
Description:
A user-defined password that prevents unauthorized changes to setpoint
temperatures and operating parameters.
Value:
0 to 9999
Resolution:
1
Default:
5000
Format:
—
Use:
Refer to section Operation, Enter Password.
NOTE: When the password is created and enabled, parameter 10 will not
appear again in the right display until the password is entered.
12 Change Hose 1 Output to Electric Gun Activation
Description:
Changes the proportioned 240 VAC current that is provided to the hose 1
heater to a switched 240 VAC current that is used to activate an electric gun.
Value:
0 (disabled)
1 (enabled)
Resolution:
—
Default:
0 (disabled)
Format:
—
Use:
For Nordson electric guns that use a switching device to evaluate an electrical
signal sent by the melter through a special receptacle.
The operating parameter is not suitable for these melters.