Operating Parameters
B-4
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
Standard (contd.)
6
Time until Service
(Non-editable)
Description:
Indicates how many more hours the heaters need to remain on before the
Service required LED lights up.
Value:
0 (disabled) to 9999 hours
Resolution:
1 hour
Default:
499
Format:
Use:
Enable the service interval (parameter 5) for this parameter to work.
7 Motor OFF Delay Not Shown
Description:
Determines the amount of time that the motor will remain on after the switching
device (e.g. foot switch, assembly handgun trigger) turns off.
Value:
0 to 360 seconds
OR
- - - - (infinite)
Resolution:
1 second
Default:
0
Format:
Use:
E.g. with assembly handguns. Pulling the trigger causes a microswitch inside
the gun to switch. This electric signal is transmitted through a special
receptacle to the melter and is evaluated there.
8 Automatic Pump On
Description:
Determines whether the pump switches on automatically when the melter is
ready.
Value:
0 (disabled)
1 (enabled)
Resolution:
Default:
1 (enabled)
Format:
Use:
When enabled, the pump can be enabled before the melter is ready. It will then
start automatically as soon as the melter is ready.
If disabled, the pump must be enabled and then, when the melter is ready,
started by pressing the pump key.
NOTE: If this operating parameter is disabled (0) while a pump is turned on, it
continues to run until the pump key is pressed.