Operating Parameters
B-9
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
25 Automatic Heaters Off
Description:
The amount of time that must elapse after Automatic standby time expires
(parameter 24) before the heaters turn off.
Value:
0 to 1440 minutes (24 hours)
Resolution:
1 minute
Default:
0 (disabled)
Format:
—
Use:
Set parameter 24 (Automatic standby) to the desired value before setting
parameter 25.
26 Standby Time
Description:
The amount of time that the melter will remain in standby mode after the
Standby key is pressed.
Value:
0 to 180 minutes
Resolution:
1 minute
Default:
0
Format:
—
Use:
Set the standby time when the operator is to place the melter in standby for a
limited period (production stoppage, lunch, etc.). Whenever standby is enabled
(value greater than 0 minutes), the Standby LED flashes, indicating that the
time is elapsing.
Set the Standby delta (parameter 23) to the desired value before setting
parameter 26.
27 Standby Delta (All Hoses)
Description:
A standby value that applies only to the hoses.
Value:
1_C to 190_C (1_F to 350_F)
Resolution:
1_C
1_F
Default:
0 (disabled)
Format:
—
Use:
If this parameter is deactivated, the standby value of parameter 23 Standby
delta (global) applies instead.
NOTE: For control purposes, the hopper belongs to the hoses.