EasyManua.ls Logo

Nordson PURBlue EC - Page 160

Nordson PURBlue EC
182 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Parameters
B-10
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
28 Standby Delta (All Guns)
Description:
A standby value that applies only to the guns.
Value:
1_C to 190_C (1_F to 350_F)
Resolution:
1_C
1_F
Default:
0 (disabled)
Format:
Use:
If this parameter is deactivated, the standby value of parameter 23 Standby
delta (global) applies instead.
29 Temperatur Offset
Description:
The grid and reservoir may be assigned different temperature setpoints.
The setpoint temperature entered on the control panel is that of the reservoir.
The grid setpoint temperature is lowered internally by the value set here. Use
the arrow keys to set the value.
Value:
0_C to 15_C (0_F to 30_F)
Resolution:
1_C
1_F
Default:
0
Format:
Use:
In case different temperatures for grid and reservoir are needed.
Setpoint Reservoir + Temperature offset = Setpoint Grid
Example: 150 _C + (15 _C) = 135 _C
NOTE: For control purposes, the hopper is hose 5. To ensure a steadily
increasing temperature hopper grid reservoir, its setpoint temperature must
be taken into consideration when setting the temperature offset.

Table of Contents

Related product manuals