Operating Parameters
B-18
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
57 Schedule 1 Enter Standby
Description:
Used to set the time that the melter enters standby during schedule 1.
Value:
0000 to 2359, - - - -
Resolution:
1 minute
Default:
- - - -
Format:
Hour, Hour: Minute, Minute
Use:
To disable this parameter, set the parameter’s value to ”- - - -” by
simultaneously pressing both of the right display scroll keys.
Note: Do not set an enter standby time that is outside of the time period defined
by the schedule’s heater on and off time. The melter can not enter standby
mode when the heaters are off.
58 Schedule 1 Exit Standby
Description:
Used to set the time that the melter will exit standby mode during schedule 1.
Value:
0000 to 2359, - - - -
Resolution:
1 minute
Default:
- - - -
Format:
Hour, Hour: Minute, Minute
Use:
To disable this parameter, set the parameter’s value to ”- - - -” by
simultaneously pressing both of the right display scroll keys.
Note: Do not set an exit standby time that is outside of the time period defined
by the schedule’s heater on and off time. The melter can not enter standby
mode when the heaters are off.
60 Schedule 2 Heaters On
Description:
Used to set the time that the clock turns on the heaters during schedule 2.
Value:
0000 to 2359, - - - -
Resolution:
1 minute
Default:
- - - -
Format:
Hour, Hour: Minute, Minute
Use:
Set the desired time for the heaters to switch on.
To disable this parameter, set the parameter’s value to ”- - - -” by
simultaneously pressing both of the right display scroll keys.