Cabinet and equipment wiring and cabling 13-73
AccessNode Series 800A Outside Plant Cabinet Installation 323-3001-210 Issue 1.0
Table 13-18 shows the BIP alarm and power cabling and wiring for the
S800A cabinet.
Table 13-18
BIP alarm and power cabling and wiring
From
Location Terminal Identification
To
Location Terminal
Alarm cabling on the pin field
BIP Pin field 7 (R05) LOW TEMP Low Temp sensor G1W
BIP Pin field 8 (RRET) LOW TEMP RET Low Temp sensor BR1W
BIP Pin field 8 (RRET) FA RET BBP Pin 2 PWR
BIP Pin field 9 (R06) FA BBP Pin 3 PWR
BIP Pin field 11 (RRET) RPTR FA RET RPTR 1 Pin 16 BL1RED
BIP Pin field 11 (RRET) RPTR LOS RET RPTR 1 Pin 10 G1RED
BIP Pin field 13 (R09) RPTR FA RPTR 1 Pin 14 SL1W
BIP Pin field 13 (R09) RPTR FA RPTR 2 Pin 14 BL1BK
BIP Pin field 14 (RRET) RPTR ERR RET RPTR 1 Pin 4 SL1RED
BIP Pin field 14 (RRET) RPTR FA RET RPTR 2 Pin 16 O1BK
BIP Pin field 15 (R10) RPTR LOS RPTR 1 Pin 8 O1RED
BIP Pin field 15 (R10) RPTR LOS RPTR 2 Pin 8 G1BK
BIP Pin field 16 (R11) RPTR ERR RPTR 1 Pin 2 BR1RED
BIP Pin field 16 (R11) RPTR ERR RPTR 2 Pin 2 SL1BK
BIP Pin field 17 (RRET) RPTR LOS RET RPTR 2 Pin 10 BR1BK
BIP Pin field 17 (RRET) RPTR ERR RET RPTR 2 Pin 4 BL1Y
—continued—