5. MAINTENANCE MENUS
Zero point adjustment of Media Thickness Sensor
1.Enter the Adjustment menu
1-1.Enter PU menu
Press the
MENU+
,
MENU-
,
OK
,
BACK
button together more than 5 sec
and stop the press when appear the following display.
Diagnostic MoDe
[[[[[[602'(
xx.xx.xx is different to PU version
Notes! Operate the following procedure, if unshown the character.
1-2.Enter Switch scan mode
Press
MENU+
button until following display.
sWitcH
  
scan
Press
OK
button when displayed.
in1 in2 in3 WR Fin
1-3.Enter Media Thickness detect mode
Press
MENU+
button until following display.(14 times)
tHicK MPt_PW t1LiFt
Press
OK
button when displayed.
tHicK MPt_PW t1LiFt
îîîżżż
xxx portion is value of Media Thickness Sensor
2.Adjustment of Media Thickness Sensor
2-1.Adjustment portion
2-2.Adjustment method
Rotate Micro Driver right and adjust xxx value of section 1-3 is following range.
260(Min) to 300(Max) (Hex number)
If the value below 260(Hex), rotate Micro Driver right. Display 000 and afterward 3FF.
Notes! Driver rotate right only. Driver must not rotate left.
Decrease the value when driver rotate right.
Work a Micro Driver into the
hole of plate.