External Reference Parameters
FQ-CR2 User’s Manual
169
Appendices
10
*1 To acquire the detected text string, use the ITEMDATA2 command.
Filter
135 Output end
digit???ntlp
Set/acquired 1 to 1024 1024 --- ---
136 Output starting
digit???ntlp
Set/acquired 1 to 1024 1 --- ---
137 Auto length Set/acquired 0: OFF 1:ON 1 --- ---
138 NG String output
on/off
Set/acquired 0: OFF 1: ON 0 --- ---
External
reference
number
Data name Set/acquired Data range Default Text string
assigned to
Ethernet
output set-
ting
Logged
0 Judgment Acquired only -2: No judgment (not inspected)
0: Judgment result OK
-1: Judgment result NG
-13: Teaching not executed error
-14: Figure not registered error
-15: Outside region error
-2 ---
---
120 1st Filter Type Set/acquired 0: None
1: Smooth
2: Dilate
3: Erosion
4: Median
0 ---
---
121 1st Filter Size Set/acquired 1: 3 × 3 2: 5 × 5 1 --- ---
123 2nd Filter Type Set/acquired 0: None
1: Smooth
2: Dilate
3: Erosion
4: Median
0 ---
---
124 2nd Filter Size Set/acquired 1: 3 × 3 2: 5 × 5 1 --- ---
126 3rd Filter Type Set/acquired 0: None
1: Smooth
2: Dilate
3: Erosion
4: Median
0 --- ---
127 3rd Filter Size Set/acquired 1: 3 × 3 2: 5 × 5 1 --- ---
External
reference
number
Data name Set/acquired Data range Default Text string
assigned to
Ethernet
output
setting
Logged
FQ Sensor User Manual.book 169 ページ 2011年7月8日 金曜日 午後2時30分