Outputting/Controlling with Ethernet
FQ-CR2 User’s Manual
131
8
Communications with External Devices
End Continuous Measurements
The command ends continuous measurements.
<Command Format>
<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
Set the Ethernet output to output measurement results.
If Ethernet output is not set, only the command response is output.
Reference: Setting the Data to Output via Ethernet (p. 120)
A S M E
CR
U R E / E
Delimiter
CR
M/E
Delimiter
or
CR
SC
Delimiter
or
CR
OK
Delimiter
CR
Measurement
result
CR
OK
CR
Delimiter
Measurement
result
Data returned
for the number
of continuous
measurements
made.
Note