Outputting/Controlling with Ethernet
FQ-CR2 User’s Manual
147
8
Communications with External Devices
Save All Sensor Information
This command saves all sensor information, including scene data and system data in the flash memory inside
the sensor.
SAVEALLDATA or SV
<Command Format>
<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
or
SATADLLAASV
E
V
CR
Delimiter
CR
Delimiter
CR
OK
Delimiter
CR
ER
Delimiter