Outputting/Controlling with Ethernet
FQ-CR2 User’s Manual
143
8
Communications with External Devices
● ITEMDATA2 Command or ID2
Acquire Inspection Item Text String Data
This command acquires the text string data of the specified Inspection Item.
<Command Format>
<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
<Parameter Descriptions>
Inspection Item number Specifies the Inspection Item number. (0 to 31)
External reference data
number
Specifies the external reference data number. (0 to 999)
Refer to 10-2 External Reference Parameters (p. 168) for details.
Acquired text string Responds with the text string data of the specified Inspection Item.
Refer to 10-2 External Reference Parameters (p. 168) for details.
I T D A T A 2
CR
E M
Inspection
item number
(2 digits max.)
Command
Space
(0×20)
Space
(0×20)
Delimiter
Delimiter
External reference
data number
(3 digits max.)
External reference
data number
(3 digits max.)
Command
or
D 2I
CR
Space
(0×20)
Space
(0×20)
Space
(0×20)
Inspection item
number
(2 digits max.)
CR
Acquired
text string
Delimiter
CR
O K
FQ Sensor User Manual.book 143 ページ 2011年7月8日 金曜日 午後2時30分