EasyManua.ls Logo

Omron FQ-CR2 - Inspection_Item_Number; External_Reference_Data_Nu; Acquires the Text String of the P. 143 Inspection Item Data

Omron FQ-CR2
193 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Outputting/Controlling with Ethernet
FQ-CR2 User’s Manual
143
8
Communications with External Devices
ITEMDATA2 Command or ID2
Acquire Inspection Item Text String Data
This command acquires the text string data of the specified Inspection Item.
<Command Format>
<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
<Parameter Descriptions>
Inspection Item number Specifies the Inspection Item number. (0 to 31)
External reference data
number
Specifies the external reference data number. (0 to 999)
Refer to 10-2 External Reference Parameters (p. 168) for details.
Acquired text string Responds with the text string data of the specified Inspection Item.
Refer to 10-2 External Reference Parameters (p. 168) for details.
I T D A T A 2
CR
E M
Inspection
item number
(2 digits max.)
Command
Space
(0×20)
Space
(0×20)
Delimiter
Delimiter
External reference
data number
(3 digits max.)
External reference
data number
(3 digits max.)
Command
or
D 2I
CR
Space
(0×20)
Space
(0×20)
Space
(0×20)
Inspection item
number
(2 digits max.)
CR
Acquired
text string
Delimiter
CR
O K
CR
ER
Delimiter
FQ Sensor User Manual.book 143 01年78日 金曜 午2時0分