Outputting/Controlling with Ethernet
140
FQ-CR2 User’s Manual
Set Filter Information
This command sets the filter type and filter size.
<Command Format>
<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
<Parameter Descriptions>
External reference data
number
Specifies the external reference data number.
Refer to 10-2 External Reference Parameters (p. 168) for details.
Setting Specifies the set value.
Refer to 10-2 External Reference Parameters (p. 168) for details.
FI DA AT
CR
LT RE
External reference data (max. 3 digits)
External reference data (max. 3 digits)
Delimiter
or
DF
CR
Delimiter
Space
(0×20)
Space
(0×20)
Space
(0×20)
Space
(0×20)
Command Set value
Command Set value
CR
OK
Delimiter
CR
ER
Delimiter
FQ Sensor User Manual.book 140 01年78日 金曜 午2時0分