Basic Troubleshooting
156
FQ-CR2 User’s Manual
9-2 Basic Troubleshooting
Problem Measures to perform Reference
The Sensor or Touch Finder will not start. Check the power supply capacity to see if it is sufficient. ---
The Sensor cannot be detected. Check the Ethernet cable to see if it is connected correctly. ---
Check the Ethernet settings to see if they are correct between the
devices.
p. 31
Check if there are any Sensors that were not detected by the Sensor
connection check.
p. 165
Check the communications cable to see if it is disconnected. ---
Check the switching hubs to see if any of them are faulty. (If switching
hubs are used.)
---
The results display is not updated. Check to see if the TRIG signal is being correctly input to the Sensor. p. 75
Check to see if the most recent NG result is being displayed. p. 14
Updating the results display is slow. If other devices are connected to the same network as the Sensor, dis-
connect the other devices from the network and check the update
speed.
If the update speed returns to normal, check the specifications of the
disconnected devices and take suitable measures.
---
If there are power lines running in parallel with the Ethernet cable or if
there are inverters or other sources of noise near the communications
cable, separate the communications cable from them and check the
update speed.
Noise may be adversely affecting the communications response.
---
Data is not logged properly. Check to see if the logging setting in the Sensor are correct. p. 76
If logging to an SD card is not possible, check the available space on the
SD card and check to see if the SD card is write-protected.
p. 84
The ERROR indicator lights. Check the error history to see what error has occurred and take suitable
measures.
p. 154
The image brightness does not stabilize. Turn ON the brightness correction mode.
When the Brightness Correction Mode is ON, the timing when images
are taken changes. Check that the images of the measured objects
taken when the Brightness Correction Mode is ON are appropriate.
p. 39
FQ Sensor User Manual.book 156 01年78日 金曜 午2時0分

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron FQ-CR2 and is the answer not in the manual?

Omron FQ-CR2 Specifications

General IconGeneral
BrandOmron
ModelFQ-CR2
CategoryBarcode Reader
LanguageEnglish

Related product manuals