Outputting/Controlling with Ethernet
FQ-CR2 User’s Manual
129
8
Communications with External Devices
Measurement Control and Measurement Acquisition Commands
MEASURE or M or GL/GC/SC
Execute Measurement
This command executes one measurement.
If Ethernet output is not set, only the measurement is performed.
If Ethernet output is set, the measurement is performed and the result is returned as response data.
<Command Format>
<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
<Parameter Descriptions>
Measurement result The measurement result is output as the response when Ethernet output is set.
The measurement result is not output when Ethernet output is not set.
Reference: Setting the Data to Output via Ethernet (p. 120)
A S M E
CR
U R E
Delimiter
CR
M
Delimiter
or
LCR
G
Delimiter
or
CR
Measurement
result
CR
OK
Delimiter
CR
ER
Delimiter
FQ Sensor User Manual.book 129 01年78日 金曜 午2時0分