EasyManuals Logo

Omron FQ-CR2 User Manual

Omron FQ-CR2
193 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #141 background imageLoading...
Page #141 background image
Outputting/Controlling with Ethernet
FQ-CR2 User’s Manual
139
8
Communications with External Devices
Data Acquisition/Setting Commands
FILTERDATA or FD
Acquire Filter Setting Information
This command acquires the filter type and filter size
<Command Format>
<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
<Parameter Descriptions>
External reference data Specifies the external reference data number
Refer to 10-2 External Reference Parameters (p. 168) for details.
Acquired value Responds with specified filter setting.
Refer to 10-2 External Reference Parameters (p. 168) for details.
FI DA AT
CR
LT RE
External reference data (max. 3 digits)
External reference data (max. 3 digits)
Delimiter
or
DF
CR
Delimiter
Space
(0×20)
Space
(0×20)
Command
Command
CR
Acquired
value
Delimiter
CR
OK
CR
ER
Delimiter
FQ Sensor User Manual.book 139 01年78日 金曜 午2時0分

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron FQ-CR2 and is the answer not in the manual?

Omron FQ-CR2 Specifications

General IconGeneral
BrandOmron
ModelFQ-CR2
CategoryBarcode Reader
LanguageEnglish

Related product manuals