EasyManuals Logo

Oracle SPARC T5-2 User Manual

Oracle SPARC T5-2
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #102 background imageLoading...
Page #102 background image
Locate a Failed DIMM (Oracle ILOM)
Note - The front and rear panel Service Required LEDs are also lit when the server detects a
DIMM fault.
Related Information
“Locate a Failed DIMM (Oracle ILOM)” on page 102
“Remove a Memory Riser and DIMM” on page 103
Locate a Failed DIMM (Oracle ILOM)
The Oracle ILOM show faulty command displays current faults, including DIMM failures.
1.
Type show faulty at the Oracle ILOM prompt.
-> show faulty
Target | Property | Value
--------------------+-------------------+-------------------
/SP/faultmgmt/0 | fru | /SYS/MB/CM0/CMP/MR1/BOB1/CH0/D0
/SP/faultmgmt/0 | timestamp | Dec 21 16:40:56
/SP/faultmgmt/0/ | timestamp | Dec 21 16:40:56 faults/0
/SP/faultmgmt/0/ | sp_detected_fault | /SYS/MB/CM0/CMP/MR1/BOB1/CH0/D0
faults/0 | | Forced fail(POST)
2.
Locate the DIMM that corresponds to the listed name.
See “Memory Riser and DIMM FRU Names” on page 97.
In this example, /SYS/MB/CM0/CMP/MR1/BOB1/CH0/D0 indicates the memory riser that is second
farthest from the power supplies and the DIMM in a slot with white handles and a black slot.
Related Information
“Locate a Failed DIMM (LEDs)” on page 100
“Remove a Memory Riser and DIMM” on page 103
102 SPARC T5-2 Server Service Manual • February 2017

Table of Contents

Other manuals for Oracle SPARC T5-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle SPARC T5-2 and is the answer not in the manual?

Oracle SPARC T5-2 Specifications

General IconGeneral
BrandOracle
ModelSPARC T5-2
CategoryServer
LanguageEnglish

Related product manuals