Remove the Server From the Rack
“Returning the Server to Operation” on page 169
Remove the Server From the Rack
You must remove the server from the rack to remove or install these components:
Motherboard
PS backplane
Drive backplane
Caution - The server chassis is heavy. To avoid personal injury, use two people to remove the
server from the rack.
1.
Shut down the host.
2.
Remove power from the server.
See “Removing Power From the Server” on page 58.
3.
Disconnect all the cables and power cords from the server.
4.
Extend the server to the maintenance position.
See “Extend the Server to the Service Position” on page 63.
5.
Release the CMA from the rail assembly.
The CMA is still attached to the cabinet, but the server chassis is now disconnected from the
CMA. See “Release the CMA” on page 64.
6.
From the front of the server, pull the release tabs forward and pull the server
forward until it is free of the rack rails.
A release tab is located on each rail.
7.
Set the server on a sturdy work surface.
Related Information
“Extend the Server to the Service Position” on page 63
“Release the CMA” on page 64
66 SPARC T5-2 Server Service Manual • February 2017

Table of Contents

Other manuals for Oracle SPARC T5-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle SPARC T5-2 and is the answer not in the manual?

Oracle SPARC T5-2 Specifications

General IconGeneral
BrandOracle
ModelSPARC T5-2
CategoryServer
LanguageEnglish

Related product manuals