Remove a Memory Riser and DIMM
Remove a Memory Riser and DIMM
Caution - These procedures require that you handle components that are sensitive to ESD. This
sensitivity can cause the component to fail. To avoid damage, ensure that you follow antistatic
practices as described in “ESD Measures” on page 54.
A customer can perform this procedure. The system must be completely powered down
before performing this procedure. See “Component Service Categories” on page 57 for more
information about cold-service procedures.
1.
Prepare for servicing:
a.
Attach an antistatic wrist strap.
b.
Power off the server and unplug power cords from the power supplies.
See “Removing Power From the Server” on page 58.
c.
Extend the server to the maintenance position.
See “Extend the Server to the Service Position” on page 63.
d.
Remove the top cover.
See “Remove the Top Cover” on page 67.