Configuring POST
Parameter Values Description
min If diag mode=normal, runs minimum set of tests.
/HOST/diag trigger none
Does not run POST on reset.
hw-change
(Default) Runs POST following a FRU replacement or an AC
power cycle.
hw_change_level
■
max (default) – Runs the maximum set of tests.
■
min – Runs the minimum set of tests.
hw_change_verbosity
■
min (default) – Displays the minimum level of output.
■
max – Displays information for each step.
■ normal – Displays a moderate amount of information,
including component names and test results.
■
debug – Displays extensive debugging information.
■
none – Disables the output.
power-on-reset
Runs POST on every power on.
power_on_level
■
max (default) – Runs the maximum set of tests.
■
min – Runs the minimum set of tests.
power_on_verbosity
■
min (default) – Displays the minimum level of output.
■
max – Displays information for each step.
■ normal – Displays a moderate amount of information,
including component names and test results.
■
debug – Displays extensive debugging information.
■
none – Disables the output.
error-reset
(Default) Runs POST if fatal errors are detected.
error_reset_level
■
max (default) – Runs the maximum set of tests.
■
min – Runs a minimum set of tests.
error_reset_verbosity
■
min (default) – Displays the minimum level of output.
■
max – Displays information for each step.
■
normal – Displays a moderate amount of information,
including component names and test results.
■
debug – Displays extensive debugging information.
■
none – Disables the output.
all-resets
Runs POST after any reset.
/HOST/diag verbosity normal
Displays all test and informational messages in POST output.
min
Displays functional tests with a banner and pinwheel in POST
output.
max
Displays all test, informational, and some debugging
messages in POST output.
debug
Displays extensive debugging information.
none
Does not display POST output.
This flowchart illustrates the same set of Oracle ILOM set command variables.
42 SPARC T5-2 Server Service Manual • February 2017