Remove a Power Supply
See “Release the CMA” on page 64.
Do not allow the CMA to hang unsupported while it is unattached.
2.
Disconnect the power cord from the power supply that displays an amber lit
Service Action Required LED.
3.
Press down on the release latch to open the ejector arm.
4.
Slide the power supply out of the chassis.
Caution - There is no “catch” mechanism on the power supply to prevent it from sliding
completely out of the chassis. Use care when removing the power supply to prevent it from
falling.
Caution - Whenever you remove a power supply, you should replace it with another power
supply. Otherwise, the server might overheat due to improper airflow. If a new power supply is
not available, leave the failed power supply installed until it can be replaced.
92 SPARC T5-2 Server Service Manual • February 2017