Configuration
36 Programming Guide
Parameter Type
Default CO
Value Range
1. CO
2. EXT
3. Qsig Master
4. Qsig Slave
Description/Function Specifies the type of each PRI port on a PRI port basis.
Notes
When you change the programming data, the status of the
card must be made OUS (Out-of-Service), and then INS (In-
Service).
The type of PRI port can be assigned per PRI23/PRI30 card.
This setting is valid when the LPR software version of the
PRI23/PRI30 card is "Q361AB"/"Q341AC" or later
respectively.
Reference 2.1 ISDN Features (F/G)
Integrated Services Digital Network (ISDN)
Integrated Services Digital Network (ISDN) Extension
3.1 TIE Line Features (F/G)
TIE Line Service
4.7 ISDN Extension Line (P/G)
Parameter DN
Default Blank
Value Range 3-4 digits consisting of 0-9 or X
Description/Function Specifies the DN (Directory Number) for the PRI port.
(Assignable only when "EXT" is specified in "Type" assignment.)
Notes
"X" can be used as a wild card character which substitutes
any digit in its position. The last one or two digits of DN may
be "X."
This setting is valid when the LPR software version of the
PRI23/PRI30 card is "Q361AB"/"Q341AC" or later
respectively.
Reference 2.3 Numbering Plan (P/G)