Programming Your Application 1-61
690+ Series Frequency Inverter
Parameter Descriptions
PARAMETER
Range: 0 to 1999
Enter the parameter to be displayed in the Operator menu. The parameter may be selected by
first choosing the block that the parameter is within, then choosing the parameter itself.
NAME
Range:16 characters maximum
Enter your customised parameter name, the maximum length is 16 characters. If this name is
left blank, then default parameter name will be used.
SCALING
Range: See below
Selects a DISPLAY SCALE function block to be applied to the value of PARAMETER.
Enumerated Value : DISPLAY SCALE function block
0 : NONE
1 : DISPLAY SCALE 1
2 : DISPLAY SCALE 2
3 : DISPLAY SCALE 3
4 : DISPLAY SCALE 4
READ ONLY
Range: FALSE / TRUE
When TRUE, this entry in the Operator Menu will not be adjustable.
IGNORE PASSWORD
Range: FALSE / TRUE
When TRUE, this entry in the Operator Menu may be adjusted regardless of the password
protection feature.