1-126 Programming Your Application
690+ Series Frequency Inverter
VALUE FUNCTION
The value function blocks can be configured to perform one of a number of functions upon a
fixed number of inputs.
Value Func 1
OUTPUT [133]
0.00
0.00
[130] INPUT A
0.00
[131] INPUT B
0.00
[132] INPUT C
IF(C) -
A
[134] TYPE
Value Func 3
OUTPUT [143]
0.00
0.00
[140] INPUT A
0.00
[141] INPUT B
0.00
[142] INPUT C
IF(C) -
A
[144] TYPE
Value Func 5
OUTPUT [153]
0.00
0.00 [150] INPUT A
0.00
[151] INPUT B
0.00
[152] INPUT C
IF(C) -
A
[154] TYPE
Value Func 7
OUTPUT [163]
0.00
0.00 [160] INPUT A
0.00
[161] INPUT B
0.00
[162] INPUT C
IF(C) -
A
[164] TYPE
Value Func 9
OUTPUT [173]
0.00
0.00 [170] INPUT A
0.00
[171] INPUT B
0.00
[172] INPUT C
IF(C) -
A
[174] TYPE
Value Func 11
OUTPUT [1299]
0.00
0.00 [1296] INPUT A
0.00
[1297] INPUT B
0.00
[1298] INPUT C
IF(C) -
A
[1300] TYPE
Value Func 13
OUTPUT [1309]
0.00
0.00 [1306] INPUT A
0.00
[1307] INPUT B
0.00
[1308] INPUT C
IF(C) -
A
[1310] TYPE
Value Func 2
OUTPUT [138]
0.00
0.00 [135] INPUT A
0.00
[136] INPUT B
0.00
[137] INPUT C
IF(C) -
A
[139] TYPE
Value Func 4
OUTPUT [148]
0.00
0.00 [145] INPUT A
0.00
[146] INPUT B
0.00
[147] INPUT C
IF(C) -
A
[149] TYPE
Value Func 6
OUTPUT [158]
0.00
0.00 [155] INPUT A
0.00
[156] INPUT B
0.00
[157] INPUT C
IF(C) -
A
[159] TYPE
Value Func 8
OUTPUT [168]
0.00
0.00 [165] INPUT A
0.00
[166] INPUT B
0.00
[167] INPUT C
IF(C) -
A
[169] TYPE
Value Func 10
OUTPUT [178]
0.00
0.00 [175] INPUT A
0.00
[176] INPUT B
0.00
[177] INPUT C
IF(C) -
A
[179] TYPE
Value Func 12
OUTPUT [1304]
0.00
0.00 [1301] INPUT A
0.00
[1302] INPUT B
0.00
[1303] INPUT C
IF(C) -
A
[1305] TYPE
Value Func 14
OUTPUT [1314]
0.00
0.00 [1311] INPUT A
0.00
[1312] INPUT B
0.00
[1313] INPUT C
IF(C) -
A
[1315] TYPE
MMI Menu Map
1
SETUP
2
MISCELLANEOUS
3
VALUE FUNC
4
VALUE FUNC 1
4
VALUE FUNC 2
4
VALUE FUNC 3
4
VALUE FUNC 4
4
VALUE FUNC 5
4
VALUE FUNC 6
4
VALUE FUNC 7
4
VALUE FUNC 8
4
VALUE FUNC 9
4
VALUE FUNC 10
INPUT A
INPUT B
INPUT C
TYPE
OUTPUT

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker 690+ series and is the answer not in the manual?

Parker 690+ series Specifications

General IconGeneral
Frequency50/60 Hz
Overload150% for 60 seconds
Communication OptionsEthernet
Protection RatingIP20
Operating Temperature0°C to 55°C
ProgrammabilityYes
Communication PortsRS485
I/O CapabilityDigital and Analog I/O
Programming LanguagesFunction Block Diagram
DimensionsVaries by module