Application Macros 5-13
690+ Series Frequency Inverter
Sequencing Logic
–
TRIPPED [289]
–
FALSE
–
RUNNING [285]
–
FALSE
–
JOGGING [302]
–
FALSE
–
STOPPING [303]
–
FALSE
–
OUTPUT CONTACTOR [286]
–
FALSE
–
SWITCH ON ENABLE [288]
–
FALSE
– SWITCHED ON [306] – FALSE
–
READY [287]
–
FALSE
–
SYSTEM RESET [305]
–
FALSE
–
SEQUENCER STATE [301]
–
START DISABLED
–
REMOTE REV OUT [296]
–
FALSE
–
HEALTHY [274]
–
TRUE
–
FAN RUNNING [620]
–
FALSE
0.000s
–
[1686] START DELAY
–
FALSE
–
[291] RUN FORWARD
–
FALSE
–
[292] RUN REVERSE
–
FALSE
–
[293] NOT STOP
–
FALSE
–
[280] JOG
–
TRUE
–
[1235] CONTACTOR CLOSED
–
TRUE
–
[276] DRIVE ENABLE
–
TRUE – [277] NOT FAST STOP –
TRUE
–
[278] NOT COAST STOP
–
FALSE
–
[294] REMOTE REVERSE
–
FALSE
–
[282] REM TRIP RESET
–
TRUE
–
[290] TRIP RST BY RUN
–
FALSE
–
[283] POWER UP START
–
I/O Trips
–
THERMIST [1155]
–
FALSE
–
ENCODER TB [1156]
–
FALSE
–
EXTERNAL [234]
–
FALSE
FALSE
–
[760] INVERT THERMIST
–
FALSE
–
[1154] INVERT ENC TRIP
–
TRIP
–
[233] EXT TRIP MODE
–
FALSE
–
[235] INPUT 1 BREAK
–
FALSE
–
[236] INPUT 2 BREAK
–
Analog Input 2
– VALUE [ 25] – 0.00 %
– BREAK [ 27] – FALSE
100.00 % – [ 23] SCALE –
0.00 % – [ 24] OFFSET –
0..+10 V – [ 22] TYPE –
FALSE – [ 21] BREAK ENABLE –
0.00 % – [ 26] BREAK VALUE –
Analog Input 3
– VALUE [715] – 0.00 %
– BREAK [717] – FALSE
100.00 % – [713] SCALE –
0.00 % – [714] OFFSET –
0..+10 V – [712] TYPE –
FALSE – [711] BREAK ENABLE –
0.00 % – [716] BREAK VALUE –
Analog Input 4
– VALUE [722] – 0.00 %
– BREAK [724] – FALSE
100.00 % – [720] SCALE –
0.00 % – [721] OFFSET –
0..+10 V – [719] TYPE –
FALSE – [718] BREAK ENABLE –
0.00 % – [723] BREAK VALUE –
Analog Output 1
0.00 % – [ 45] VALUE –
100.00 % – [ 46] SCALE –
0.00 % – [ 47] OFFSET –
TRUE – [ 48] ABSOLUTE –
0..+10 V – [ 49] TYPE –
Analog Output 2
0.00 % – [731] VALUE –
100.00 % – [732] SCALE –
0.00 % – [733] OFFSET –
FALSE – [734] ABSOLUTE –
-10 .. +10 V – [735] TYPE –
Digital Input 1
VALUE [ 31] – FALSE
FALSE – [ 30] INVERT –
Digital Input 3
VALUE [ 37] – FALSE
FALSE – [ 36] INVERT –
Digital Input 5
VALUE [ 43] – FALSE
FALSE – [ 42] INVERT –
Digital Input 2
VALUE [ 34] – FALSE
FALSE – [ 33] INVERT –
Digital Input 4
VALUE [ 40] – FALSE
FALSE – [ 39] INVERT –
Digital Input 6
VALUE [726] – FALSE
FALSE – [725] INVERT –
Digital Input 7
VALUE [728] – FALSE
FALSE – [727] INVERT –
Digital Output 1
FALSE – [ 52] VALUE –
TRUE – [ 51] INVERT –
Digital Output 2
FALSE – [ 55] VALUE –
FALSE – [ 54] INVERT –
Digital Output 3
FALSE – [737] VALUE –
FALSE – [736] INVERT –
Minimum Speed
OUTPUT [335] – 0.00 %
0.00 % – [336] INPUT –
-100.00 % – [337] MINIMUM –
PROP. W/MIN. – [338] MODE –
Reference
SPEED DEMAND [255] – 0.00 %
SPEED SETPOINT [254] – 0.00 %
REVERSE [256] –FALSE
LOCAL SETPOINT [247] – 0.00 %
LOCAL REVERSE [250] – FALSE
COMMS SETPOINT [770] –0.00 %
0.00 % – [245] REMOTE SETPOINT –
0.00 % – [248] SPEED TRIM –
110.00 % – [252] MAX SPEED CLAMP –
-110.00 % – [253] MIN SPEED CLAMP –
FALSE – [243] TRIM IN LOCAL –
FALSE – [249] REMOTE REVERSE –
Reference Jog
10.00 % – [246] SETPOINT –
1.0 s – [261] ACCEL TIME –
1.0 s – [262] DECEL TIME –
Reference Stop
STOP RAMP – [279] RUN STOP MODE –
10.0 s – [263] STOP TIME –
0.10 % – [266] STOP ZERO SPEED –
0.500 s – [284] STOP DELAY –
RAMPED – [304] FAST STOP MODE –
30.0 s – [275] FAST STOP LIMIT –
0.1 s – [264] FAST STOP TIME –
1200 Hz/s – [126] FINAL STOP RATE –
Skip Frequencies
OUTPUT [346] –0.00 %
OUTPUT HZ [363] – 0.0 Hz
INPUT HZ [362] – 0.0 Hz
0.00 % – [340] INPUT –
0.0 Hz – [341] BAND 1 –
0.0 Hz – [342] FREQUENCY 1 –
0.0 Hz – [680] BAND 2 –
0.0 Hz – [343] FREQUENCY 2 –
0.0 Hz – [681] BAND 3 –
0.0 Hz – [344] FREQUENCY 3 –
0.0 Hz – [682] BAND 4 –
0.0 Hz – [345] FREQUENCY 4 –
Trips Status
ACTIVE TRIPS [ 4] – 0000
ACTIVE TRIPS+ [740] – 0000
WARNINGS [ 5] –0000
WARNINGS+ [741] –0000
FIRST TRIP [ 6] – NONE
0700 – [231] DISABLED TRIPS –
0040 – [742] DISABLED TRIPS+ –
Value Func 1
OUTPUT [133] – 0.00 %
0.00 % – [130] INPUT A –
0.00 % – [131] INPUT B –
0.00 % – [132] INPUT C –
A+B+C – [134] TYPE –
Analog Input 1
– VALUE [ 16] – 0.00 %
– BREAK [ 18] – FALSE
100.00 % – [ 14] SCALE –
0.00 % – [ 15] OFFSET –
0..+10 V – [ 13] TYPE –
FALSE – [ 12] BREAK ENABLE –
0.00 % – [ 17] BREAK VALUE –
Analog Output 3
0.00 % – [800] VALUE –
100.00 % – [801] SCALE –
0.00 % – [802] OFFSET –
FALSE – [803] ABSOLUTE –
– [804] TYPE –-10 .. +10 V
(1)
(3)
(2)
(4)
(12)
(13)
(14)
(16)
(17)
(18)
(5)
(6)
(7)
(11)
0.00 %
Setpoint Scale
– OUTPUT [ 59] – 0.0 Hz
– [ 58] INPUT –
** 1500 RPM
– [1032] MAX SPEED –
(19)
(20)
INPUT 0
Preset 1
OUTPUT 1 [356] – 0.00
OUTPUT 2 [372] – 0.00
– [355] SELECT INPUT –
0.00 – [347] INPUT 0 –
25.00 – [348] INPUT 1 –
50.00 – [349] INPUT 2 –
100.00
– [350] INPUT 3 –
0.00 – [351] INPUT 4 –
0.00 – [352] INPUT 5 –
0.00 – [353] INPUT 6 –
0.00 – [354] INPUT 7 –
(21)
0.00
0.00
0.00
Value Func 2
OUTPUT [138] –
– [135] INPUT A –
– [136] INPUT B –
0.00
– [137] INPUT C –
BIN DECODE
– [139] TYPE –
(8)
(9)
(10)
(15)
Reference Ramp
– RAMPING [698] – FALSE
LINEAR – [244] RAMP TYPE –
** 10.0 s
– [258] ACCEL TIME –
** 10.0 s
– [259] DECEL TIME –
FALSE – [268] SYMMETRIC MODE –
** 10.0 s
– [267] SYMMETRIC TIME –
10.00 /s^2 – [692] SRAMP ACCEL –
10.00 /s^2 – [693] SRAMP DECEL –
10.00 /s^3 – [694] SRAMP JERK 1 –
10.00 /s^3 – [695] SRAMP JERK 2 –
10.00 /s^3 – [696] SRAMP JERK 3 –
10.00 /s^3 – [697] SRAMP JERK 4 –
TRUE – [691] SRAMP CONTINUOUS –
FALSE – [260] HOLD –
Macro 5: Preset Speeds