Application Macros 5-17
690+ Series Frequency Inverter
Sequencing Logic
TRIPPED [289]
FALSE
RUNNING [285]
FALSE
JOGGING [302]
FALSE
STOPPING [303]
FALSE
OUTPUT CONTACTOR [286]
FALSE
SWITCH ON ENABLE [288]
FALSE
SWITCHED ON [306] FALSE
READY [287]
FALSE
SYSTEM RESET [305]
FALSE
SEQUENCER STATE [301]
START DISABLED
REMOTE REV OUT [296]
FALSE
HEALTHY [274]
TRUE
FAN RUNNING [620]
FALSE
0.000s
[1686] START DELAY
FALSE
[291] RUN FORWARD
FALSE
[292] RUN REVERSE
FALSE
[293] NOT STOP
FALSE
[280] JOG
TRUE
[1235] CONTACTOR CLOSED
TRUE
[276] DRIVE ENABLE
TRUE [277] NOT FAST STOP
TRUE
[278] NOT COAST STOP
FALSE
[294] REMOTE REVERSE
FALSE
[282] REM TRIP RESET
TRUE
[290] TRIP RST BY RUN
FALSE
[283] POWER UP START
Digital Output 3
FALSE [737] VALUE
FALSE [736] INVERT
0.00 %
Reference
SPEED DEMAND [255] 0.00 %
SPEED SETPOINT [254] 0.00 %
REVERSE [256] FALSE
LOCAL SETPOINT [247] 0.00 %
LOCAL REVERSE [250] FALSE
COMMS SETPOINT [770] 0.00 %
[245] REMOTE SETPOINT
0.00 % [248] SPEED TRIM
110.00 % [252] MAX SPEED CLAMP
-110.00 % [253] MIN SPEED CLAMP
FALSE [243] TRIM IN LOCAL
FALSE [249] REMOTE REVERSE
Analog Input 1
VALUE [ 16] 0.00 %
BREAK [ 18] FALSE
100.00 % [ 14] SCALE
0.00 % [ 15] OFFSET
[ 13] TYPE
FALSE [ 12] BREAK ENABLE
0.00 % [ 17] BREAK VALUE
-10 .. 10 V
0.00 %
FALSE
Analog Input 3
VALUE [715]
BREAK [717]
100.00 % [713] SCALE
0.00 % [714] OFFSET
-10 .. 10 V
[712] TYPE
FALSE [711] BREAK ENABLE
0.00 % [716] BREAK VALUE
Analog Input 2
VALUE [ 25] 0.00 %
BREAK [ 27] FALSE
100.00 % [ 23] SCALE
0.00 % [ 24] OFFSET
[ 22] TYPE
FALSE [ 21] BREAK ENABLE
0.00 % [ 26] BREAK VALUE
-10 .. 10 V
I/O Trips
THERMIST [1155]
FALSE
ENCODER TB [1156]
FALSE
EXTERNAL [234]
FALSE
FALSE
[760] INVERT THERMIST
FALSE
[1154] INVERT ENC TRIP
COAST
[233] EXT TRIP MODE
FALSE
[235] INPUT 1 BREAK
FALSE
[236] INPUT 2 BREAK
Analog Input 4
VALUE [722] 0.00 %
BREAK [724] FALSE
100.00 % [720] SCALE
0.00 % [721] OFFSET
0..+10 V [719] TYPE
FALSE [718] BREAK ENABLE
0.00 % [723] BREAK VALUE
Analog Output 1
0.00 % [ 45] VALUE
100.00 % [ 46] SCALE
0.00 % [ 47] OFFSET
TRUE [ 48] ABSOLUTE
0..+10 V [ 49] TYPE
Analog Output 2
0.00 % [731] VALUE
100.00 % [732] SCALE
0.00 % [733] OFFSET
FALSE [734] ABSOLUTE
-10 .. +10 V [735] TYPE
Digital Input 1
VALUE [ 31] FALSE
FALSE [ 30] INVERT
Digital Input 3
VALUE [ 37] FALSE
FALSE [ 36] INVERT
Digital Input 5
VALUE [ 43] FALSE
FALSE [ 42] INVERT
Digital Input 2
VALUE [ 34] FALSE
FALSE [ 33] INVERT
Digital Input 4
VALUE [ 40] FALSE
FALSE [ 39] INVERT
Digital Input 6
VALUE [726] FALSE
FALSE [725] INVERT
Digital Input 7
VALUE [728] FALSE
FALSE [727] INVERT
Digital Output 1
FALSE [ 52] VALUE
TRUE [ 51] INVERT
Digital Output 2
FALSE [ 55] VALUE
FALSE [ 54] INVERT
Reference Jog
10.00 % [246] SETPOINT
1.0 s [261] ACCEL TIME
1.0 s [262] DECEL TIME
Reference Stop
STOP RAMP [279] RUN STOP MODE
10.0 s [263] STOP TIME
0.10 % [266] STOP ZERO SPEED
0.500 s [284] STOP DELAY
RAMPED [304] FAST STOP MODE
30.0 s [275] FAST STOP LIMIT
0.1 s [264] FAST STOP TIME
1200 Hz/s [126] FINAL STOP RATE
Trips Status
ACTIVE TRIPS [ 4] 0000
ACTIVE TRIPS+ [740] 0000
WARNINGS [ 5] 0000
WARNINGS+ [741] 0000
FIRST TRIP [ 6] NONE
0700 [231] DISABLED TRIPS
0040 [742] DISABLED TRIPS+
Value Func 1
OUTPUT [133] 0.00 %
0.00 % [130] INPUT A
0.00 % [131] INPUT B
0.00
[132] INPUT C
A+B+C [134] TYPE
Analog Output 3
0.00 % [800] VALUE
100.00 % [801] SCALE
0.00 % [802] OFFSET
FALSE [803] ABSOLUTE
[804] TYPE -10 .. +10 V
(13)
(16)
(5)
(6)
(7)
(9)
0.00 %
Setpoint Scale
OUTPUT [ 59] 0.0 Hz
[ 58] INPUT
** 1500 RPM [1032] MAX SPEED
(21)
(18)
Digital Input 8 = COAST STOP
Motor Data
** SENSORLESS VEC
[1157] CONTROL MODE
** 5.50 kW [1158] POWER
** 50.0 Hz [1159] BASE FREQUENCY
** 400.0 V [1160] MOTOR VOLTAGE
** 11.30 A [ 64] MOTOR CURRENT
** 3.39 A [ 65] MAG CURRENT
** 1445.0 rpm [ 83] NAMEPLATE RPM
** STAR [124] MOTOR CONNECTION
** 4 [ 84] MOTOR POLES
** 0.90 [242] POWER FACTOR
** 2.0 [1164] OVERLOAD
** 1.3625 Ohm [119] STATOR RES
** 43.37 mH [120] LEAKAGE INDUC
** 173.48 mH [121] MUTUAL INDUC
276.04 ms [1163] ROTOR TIME CONST
Feedbacks
DC LINK VOLTS [ 75] 0 V
TERMINAL VOLTS [1020] 0 V
SPEED FEEDBACK RPM [569] 0.00 rpm
SPEED FEEDBACK HZ [568] 0.00 Hz
SPEED FEEDBACK % [749] 0.00 %
ENCODER FBK % [1238] 0.00 %
ENCODER COUNT [1016] 0
TORQUE FEEDBACK [ 70] 0.00 %
FIELD FEEDBACK [ 73] 0.00 %
MOTOR CURRENT % [ 66] 0.00 %
MOTOR CURRENT [ 67] 0.0 A
** 10.0 V [761] ENCODER SUPPLY
** 2048 [566] ENCODER LINES
** FALSE [567] ENCODER INVERT
** FALSE [ 50] QUADRATIC TORQUE
Zero Speed
AT ZERO SPD FBK [1233] TRUE
AT ZERO SPD DMD [360] TRUE
AT STANDSTILL [1234] TRUE
0.00 % [359] HYSTERISIS
0.00 % [357] THRESHOLD
(15)
(19)
(8)
(10)
(14)
(20)
(17)
Phase Control SPEED INPUT (next sheet)
Phase PID OUTPUT (next sheet)
5703 Input
SCALED VALUE [1260]
0.00
RAW VALUE [1261] 0.00
BREAK [1262] FALSE
1.0000
[1258] RATIO
FALSE
[1259] NEGATE
0.00
5703 Output
[1263] VALUE
FALSE [1264] REPEATER
Phase Configure MAX SPEED (next sheet)
Reference Ramp
RAMPING [698] FALSE
LINEAR [244] RAMP TYPE
** 10.0 s
[258] ACCEL TIME
** 10.0 s
[259] DECEL TIME
FALSE [268] SYMMETRIC MODE
** 10.0 s
[267] SYMMETRIC TIME
10.00 /s^2 [692] SRAMP ACCEL
10.00 /s^2 [693] SRAMP DECEL
10.00 /s^3 [694] SRAMP JERK 1
10.00 /s^3 [695] SRAMP JERK 2
10.00 /s^3 [696] SRAMP JERK 3
10.00 /s^3 [697] SRAMP JERK 4
TRUE [691] SRAMP CONTINUOUS
FALSE [260] HOLD
Note: Download from CeLite using the Operator Station Comms port (not the P3 port)
Macro 7: Phase/Register