Application Macros 5-9
690+ Series Frequency Inverter
Sequencing Logic
TRIPPED [289]
FALSE
RUNNING [285] FALSE
JOGGING [302]
FALSE
STOPPING [303]
FALSE
OUTPUT CONTACTOR [286] FALSE
SWITCH ON ENABLE [288] FALSE
SWITCHED ON [306] FALSE
READY [287]
FALSE
SYSTEM RESET [305] FALSE
SEQUENCER STATE [301]
START DISABLED
REMOTE REV OUT [296] FALSE
HEALTHY [274] TRUE
FAN RUNNING [620] FALSE
0.000s [1686] START DELAY
FALSE [291] RUN FORWARD
FALSE
[292] RUN REVERSE
FALSE
[293] NOT STOP
FALSE [280] JOG
TRUE
[1235] CONTACTOR CLOSED
TRUE
[276] DRIVE ENABLE
TRUE [277] NOT FAST STOP
TRUE [278] NOT COAST STOP
FALSE [294] REMOTE REVERSE
FALSE
[282] REM TRIP RESET
TRUE [290] TRIP RST BY RUN
FALSE [283] POWER UP START
I/O Trips
THERMIST [1155] FALSE
ENCODER TB [1156]
FALSE
EXTERNAL [234]
FALSE
FALSE
[760] INVERT THERMIST
FALSE
[1154] INVERT ENC TRIP
TRIP
[233] EXT TRIP MODE
FALSE
[235] INPUT 1 BREAK
FALSE
[236] INPUT 2 BREAK
Analog Input 2
VALUE [ 25]
0.00 %
BREAK [ 27]
FALSE
100.00 %
[ 23] SCALE
0.00 %
[ 24] OFFSET
-10..+10 V
[ 22] TYPE
FALSE
[ 21] BREAK ENABLE
0.00 %
[ 26] BREAK VALUE
Analog Input 3
VALUE [715]
0.00 %
BREAK [717]
FALSE
100.00 %
[713] SCALE
0.00 %
[714] OFFSET
0..+10 V
[712] TYPE
FALSE
[711] BREAK ENABLE
0.00 %
[716] BREAK VALUE
Analog Input 4
VALUE [722]
0.00 %
BREAK [724]
FALSE
100.00 %
[720] SCALE
0.00 %
[721] OFFSET
0..+10 V
[719] TYPE
FALSE
[718] BREAK ENABLE
0.00 %
[723] BREAK VALUE
Analog Output 1
0.00 %
[ 45] VALUE
100.00 %
[ 46] SCALE
0.00 %
[ 47] OFFSET
TRUE
[ 48] ABSOLUTE
0..+10 V
[ 49] TYPE
Analog Output 2
0.00 %
[731] VALUE
100.00 %
[732] SCALE
0.00 %
[733] OFFSET
FALSE
[734] ABSOLUTE
0 .. +10 V
[735] TYPE
Digital Input 1
VALUE [ 31]
FALSE
FALSE [ 30] INVERT
Digital Input 3
VALUE [ 37]
FALSE
FALSE [ 36] INVERT
Digital Input 5
VALUE [ 43]
FALSE
FALSE [ 42] INVERT
Digital Input 2
VALUE [ 34]
FALSE
FALSE [ 33] INVERT
Digital Input 4
VALUE [ 40]
FALSE
FALSE [ 39] INVERT
Digital Input 6
VALUE [726]
FALSE
FALSE [725] INVERT
Digital Input 7
VALUE [728]
FALSE
FALSE [727] INVERT
Digital Output 1
FALSE [ 52] VALUE
TRUE
[ 51] INVERT
Digital Output 2
FALSE [ 55] VALUE
FALSE
[ 54] INVERT
Digital Output 3
FALSE [737] VALUE
FALSE
[736] INVERT
Reference
SPEED DEMAND [255]
0.00 %
SPEED SETPOINT [254]
0.00 %
REVERSE [256]
FALSE
LOCAL SETPOINT [247]
0.00 %
LOCAL REVERSE [250]
FALSE
COMMS SETPOINT [770]
0.00 %
0.00 %
[245] REMOTE SETPOINT
0.00 %
[248] SPEED TRIM
110.00 %
[252] MAX SPEED CLAMP
-110.00 %
[253] MIN SPEED CLAMP
FALSE
[243] TRIM IN LOCAL
FALSE
[249] REMOTE REVERSE
Reference Jog
10.00 %
[246] SETPOINT
1.0 s
[261] ACCEL TIME
1.0 s
[262] DECEL TIME
Reference Ramp
RAMPING [698]
FALSE
LINEAR
[244] RAMP TYPE
** 10.0 s
[258] ACCEL TIME
** 10.0 s
[259] DECEL TIME
FALSE
[268] SYMMETRIC MODE
** 10.0 s
[267] SYMMETRIC TIME
10.00 /s^2
[692] SRAMP ACCEL
10.00 /s^2
[693] SRAMP DECEL
10.00 /s^3
[694] SRAMP JERK 1
10.00 /s^3
[695] SRAMP JERK 2
10.00 /s^3
[696] SRAMP JERK 3
10.00 /s^3
[697] SRAMP JERK 4
TRUE
[691] SRAMP CONTINUOUS
FALSE
[260] HOLD
Reference Stop
STOP RAMP
[279] RUN STOP MODE
10.0 s
[263] STOP TIME
0.10 %
[266] STOP ZERO SPEED
0.500 s
[284] STOP DELAY
RAMPED
[304] FAST STOP MODE
30.0 s
[275] FAST STOP LIMIT
0.1 s
[264] FAST STOP TIME
1200 Hz/s
[126] FINAL STOP RATE
Trips Status
ACTIVE TRIPS [ 4]
0000
ACTIVE TRIPS+ [740]
0000
WARNINGS [ 5]
0000
WARNINGS+ [741]
0000
FIRST TRIP [ 6]
NONE
0700 [231] DISABLED TRIPS
0040 [742] DISABLED TRIPS+
-10..+10 V
Analog Input 1
VALUE [ 16]
0.00 %
BREAK [ 18]
FALSE
100.00 %
[ 14] SCALE
0.00 %
[ 15] OFFSET
[ 13] TYPE
FALSE
[ 12] BREAK ENABLE
0.00 %
[ 17] BREAK VALUE
Analog Output 3
0.00 %
[800] VALUE
100.00 %
[801] SCALE
0.00 %
[802] OFFSET
FALSE
[803] ABSOLUTE
[804] TYPE
-10 .. +10 V
(2)
(4)
(14)
(10)
(12)
(6)
0.00 %
Setpoint Scale
OUTPUT [ 59]
0.0 Hz
[ 58] INPUT
** 1500 RPM
[1032] MAX SPEED
(17)
(18)
(13)
(1)
(3)
(38)
(5)
(15)
(16)
(9)
(19)
(20)
(11)
Line Speed ANIN1 (next sheet)
Feedback ANIN2 (next sheet)
Run DIN1 (next sheet)
Tension Spt ANIN3 (next sheet)
Switched On (next sheet)
Taper Spt ANIN4 (next sheet)
Diameter ANOUT2 (next sheet)
Tension/Dancer Spt ANOUT3 (next sheet)
Speed Demand (next sheet)
(7)
(35)
(37)
(36)
(8)
Macro 4: Speed Programmed Winder (SPW)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker 690+ series and is the answer not in the manual?

Parker 690+ series Specifications

General IconGeneral
Frequency50/60 Hz
Overload150% for 60 seconds
Communication OptionsEthernet
Protection RatingIP20
Operating Temperature0°C to 55°C
ProgrammabilityYes
Communication PortsRS485
I/O CapabilityDigital and Analog I/O
Programming LanguagesFunction Block Diagram
DimensionsVaries by module