Parameter Specification 2-41
690+ Series Frequency Inverter
6053 Technology Box Dependent Parameters
The parameters shown below have special scaling rules applied when using 6053 Technology
Box comms options.
TAG MMI Name Block Decimal Point position used by
Comms Interface
64 MOTOR CURRENT MOTOR DATA _.x
65 MAG CURRENT MOTOR DATA _.x
83 NAMEPLATE RPM MOTOR DATA _.
119 STATOR RES MOTOR DATA _.xx
121 MUTUAL INDUC MOTOR DATA _.x
568 SPEED FBK REV/S FEEDBACKS _.
569 SPEED FBK RPM FEEDBACKS _.
846 TENSION RAMP TAPER CALC _.xx
1158 POWER MOTOR DATA _.x
1163 ROTOR TIME CONST MOTOR DATA _.x
1190 SPEED INT PRESET SPEED LOOP _.x
1197 DIRECT RATIO SPEED LOOP _.xxx
1203 TOTL SPD DMD RPM SPEED LOOP _.
1483 GEARING A PHASE CONTROL _.
1484 GEARING B PHASE CONTROL _.
1519 LIMIT PHASE PID _.xx
77 BRAKE RES DYNAMIC BRAKING _.
Product-Related Default Values
All examples given in this book are based on a UK, 400V, 50Hz, 7.5kW Inverter.
* Frequency Dependent Defaults
These parameter values (marked with “*” in function block descriptions and macro diagrams)
are dependent upon the drive’s default motor base frequency. The following table lists the
changes to the “
** Power Dependent Defaults” tables below for t
hose parameters whose settings
are adjusted for operation at 60Hz.
Parameter Function Block Tag 60Hz Operation
BASE FREQUENCY MOTOR DATA 1159 60Hz
MOTOR CONNECTION MOTOR DATA 124 STAR
MOTOR VOLTAGE MOTOR DATA 1160 *
NAMEPLATE RPM MOTOR DATA 83 1750 RPM
MAX SPEED SETPOINT SCALE 1032 1800 RPM
BASE FREQUENCY FLUXING 106 60.0Hz
* 230V unit : 230V, 400V unit : 460V, 500V unit : 500V
** Power Dependent Defaults
These parameters (marked with “**” in function block descriptions and macro diagrams) are set
to a value depending on the overall “power-build” of the Inverter indicated by the Product Code.
FRAME B - 230V Build Power Dependent Defaults
Single Phase Three Phase
Parameter Function Block Tag 0.75kW 1.5kW 2.2kW 0.75kW 1.5kW 2.2kW 4kW
ACCEL TIME REFERENCE RAMP 258 10.0 10.0 10.0 10.0 10.0 10.0 10.0
AUTO BOOST FLUXING 108 0.00 0.00 0.00 0.00 0.00 0.00 0.00
BASE FREQUENCY MOTOR DATA 1159 50.0 50.0 50.0 50.0 50.0 50.0 50.0
CONTROL MODE MOTOR DATA 1157 VOLTS
/ HZ
VOLTS
/ HZ
VOLTS
/ HZ
VOLTS
/ HZ
VOLTS
/ HZ
VOLTS
/ HZ
VOLTS
/ HZ

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker 690+ series and is the answer not in the manual?

Parker 690+ series Specifications

General IconGeneral
Frequency50/60 Hz
Overload150% for 60 seconds
Communication OptionsEthernet
Protection RatingIP20
Operating Temperature0°C to 55°C
ProgrammabilityYes
Communication PortsRS485
I/O CapabilityDigital and Analog I/O
Programming LanguagesFunction Block Diagram
DimensionsVaries by module