The following assumptions are made:
The current station is the foresight point of the previous station which you select as a
next station. The back sight point of current station is the previous station.
The following limitations are made:
More than one traverse route can’t be measured at the same time. Don’t store other data
while you are measuring the traverse route. When one traverse route is finished, perform
the traverse calculation before you store other data. Don’t turn the power supply off
until the measurement at one start point or at one corner point is completed.
Don’t escape from the MEASURE screen.
You can’t use a duplicate PN in one Job. And you can’t overwrite the PN in the traverse.
The same traverse route can’t be calculated again. Polar coordinates data of back sight
and station points can’t be seen in the EDIT THE POLAR DATA function. But it is sent
properly in SEND POLAR DATA function.
Traverse
From the PowerTopoLite, Press the [F1][TRAV] of the PowerTopoLite to view the
TRAVERSE screen.
Closed traverse
Open traverse