6. FREE STATIONING
The Station point Coordinates are calculated from the different known points.
To gain the Coordinates, at least two H. angles and one distance or three H. angles
are required.
If not so, the error message of “Not enough data to Calculate! 2 angles and 1 distance, 3
angles are required” appears.
First, input the height of the IH, Instrument height.
6.1 Stationing by more than 3 known points
4 known points stationing (For example)
Press [F4][FREE] of the PowerTopoLite screen to
view the IH input screen.
Input the IH value.
?
Point 1
Coordinates
Station Point Coordinates
Point 2 Coordinates
Point 3
Coordinates
Point 4 Coordinates
IH

Table of Contents