141
Select 9.Elevation factor and press [ENT] to view
the ELEVATION FACTOR selection window. Press
[ENT] to select and press [F5][ACCEPT].
1. Average Elevation
Average (H) = Averaged on-site elevation
Input range: -9999.9998 -- +9999.9998m
2. Scale Factor
Scaling = On-site scaling coefficient
Input range: +0.00000001 -- +1.99999998
14.10 Duplicate point check
When for this setting ON is selected, you can check
whether a Point Name overlaps another Point Name
already input.