EasyManuals Logo

Pentax R-2500NS Series User Manual

Pentax R-2500NS Series
145 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #99 background imageLoading...
Page #99 background image
98
11. TRAVERSE
This function is for fixed, closed and open traverse calculations.
You can measure not only the corner points but also the sideshot points at the same time.
When the traverse is closed, the closing errors of coordinates are calculated and the corner
points can be adjusted. In addition, the sideshot points from the corner point based on the
adjusted each corner point’s coordinates are calculated.
One point of the traverse data uses the memory size of two or three coordinates data.
Therefore, please check the remaining memory.
The calculation type is the Compass Rule.
The traverse function can store the polar coordinates data and the rectangular coordinates
data. And it can send the polar data by DC1 or AUX format and rectangular data by DC1 or
CSV format respectively.
Fixed traverse
Start point
(Coordinates)
End point
(Coordinates)
Direction angle
Back sight point
Sideshot point
Corner point
Known point

Table of Contents