101
Input the TEMP value.
Press [ENT].
Input the PRESS value.
Press [ENT].
Input the ppm value.
TEMP, PRESS and ppm input depend on the Initial setting 1 (ATM INPUT, ppm INPUT,
NIL). And they are alternative.
Press [F5][ACCEPT] to save the input data.
Then it proceeds to STATION POINT H. ANGLE SETUP screen automatically.
Station Orientation
Input the back sight point’s direction angle from the
start point.
NOTE: The direction angle set at this screen is used in the traverse calculation which will be
executed later.
And the rotation of the “H.angle” depends on the rotation setting of
“14 .2 Coordinate axis definition”.
[INVERS] key
If you want to calculate the direction angle, press [F5][INVERS] to jump INVERSE
function.
Input SP as a start point and EP as a back sight point.
Result angle is set here automatically by pressing the [ENT] at the RESULT OF INVERSE
screen. Press [ENT] after aiming at the reference point.