119
• The number of data exceeds the maximum number of job files stored in the internal
memory.
If the total number of points in all job files exceeds the maximum number of points stored
in the internal memory, an error message [WARNING This job file was exceeded] is
displayed.
(6000 points for R-2501N, R-2502N and R-2503N, 5000 points for R-2505N).
In this case, up to the maximum number can be read, but after that no more.
[Suitability of SD card]
• The SD card that can be used with the instrument is 1GB or less.
• SD card and SD logo is registered trademark.
• The SD cards listed in the following table have been tested by us and
it has been confirmed that the SD cards can be used with the R-2500NS series.
This test has been done with only the Pentax R-2500NS series Total Station, but no other
Pentax
Total Stations. When using with other Pentax Total Stations, please contact us to confirm
it works properly.
It has also been confirmed that the models mentioned in the following table can be used with
the R-2500NS series Total Station. Other brands or models of SD cards are not confirmed by
us.
Please note that the test has been done by us and that this does not mean that each SD card
manufacturer guarantees that the SD cards can be used with the Pentax R-2500NS series.
SD(micro SD)Card
Make sure to use the adaptor when using a microSD.
• Regardless of the information mentioned here, take note that not all SDHC cards can be
used with the R-2500NS Total Stations.
• Test item:The following has been done according to our Test Standards.
① When data is being sent (by connecting USB), it is necessary to be able to refer to
information on the SD card from PC and to operate the file.
② When writing/reading text, it is necessary to be able to read/write text file.