6.6 Using the simulation function
You can simulate a project if you do not want it to be transferred to a controller. To use the
simulation function, proceed as follows:
• Double-click on the controller node in the “PLANT” area.
The “axcf1050-1” editor group opens.
• Select the “Cockpit” editor.
Select “Simulation” from the drop-down list (see Figure 6-5).
Figure 6-5 Setting up a simulation
• Click on the button (“Write project to controller and start execution. (F5)”).
The project is compiled, sent to the simulation and started.
The simulation includes a web server. If the project includes a PC Worx Engineer HMI ap-
plication (see Section 6.14), the web server provides the PC Worx Engineer HMI applica-
tion and processes the generated HMI pages.